Product Description

Q1: What information do I need to provide to get the suitable machine?
1. How much air delivery capacity ( Unit:CFM or M3/Min )
2 How much working pressure ( Unit:PSI, Bar or Mpa )
3.What is the voltage and frequency of my country of residence ( V/Hz )
4. Whether I need other accessories such as air tank, filters and/or air dryers.
Tell us the answer, we will offer scheme for you!

Q2: What are the general unit conversion?
1bar = 0.1Mpa = 14.5psi 1m³/min = 35.32cfm 1KW = 1.34HP

Q3: Are you factory or trading company?
We are factory. Our factory is located in 39 Xihu (West Lake) Dis. Rd, HangZhou, ZHangZhoug

Q4: Which trade term can you accept?
FOB, CIF, CFR, EXW, etc.

Q5: How long will you take to arrange production?
15 days for Regular Products, 35 days for Customizing Models

SPECIFICATION

MODEL LZN-10-15
Ambient Temperature -5ºC to +45 ºC
Max Pressure (bar) 15
Air Delivery (m3/min) 1.0 
Compression Stage Single Stage Compression
Cooling Method Air Cooled
Discharge Temperature (ºC) ≤ 75ºC
Oil  Cotent (ppm) ≤3
Transmission Method Belt Driven
Sound Level dB(A) 66±3
Lubricating Oil Amount 3.5L
Motor Power 7.5KW/10HP
Motor Level Of Protection  IP55
Voltage 380V/3ph/50Hz
Dimensions (mm) 1570×650×1452(L*W*H)
Weight 435KG
Discharge Outlet Thread 1/2”

/* March 10, 2571 17:59:20 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

After-sales Service: Video, Live, Site Support
Warranty: 2-Year-Warranty
Lubrication Style: Lubricated
Cooling System: Air Cooling
Power Source: AC Power
Installation Type: Movable Type
Samples:
US$ 1450/set
1 set(Min.Order)

|
Request Sample

Customization:
Available

|

air compressor

What Safety Precautions Should Be Taken When Operating Screw Compressors?

When operating screw compressors, it is important to follow specific safety precautions to ensure the well-being of personnel and prevent potential accidents. Here’s a detailed explanation:

1. Familiarize Yourself with the Equipment:

  • Before operating a screw compressor, thoroughly read and understand the manufacturer’s instructions, safety guidelines, and operating procedures. Familiarize yourself with the specific features, controls, and safety devices of the compressor.

2. Wear Appropriate Personal Protective Equipment (PPE):

  • Wear the necessary PPE, such as safety glasses, hearing protection, gloves, and appropriate clothing, when operating the compressor. PPE helps protect against potential hazards, including flying debris, noise, and contact with hot or moving parts.

3. Ensure Proper Ventilation:

  • Operate the screw compressor in a well-ventilated area to prevent the buildup of potentially harmful gases or fumes. Ensure that the compressor’s intake and exhaust vents are not obstructed, allowing for adequate airflow.

4. Compressor Location:

  • Position the compressor on a stable and level surface to prevent tipping or instability during operation. Ensure that the compressor is located away from flammable materials, heat sources, or sources of ignition.

5. Electrical Safety:

  • Follow electrical safety guidelines and ensure that the compressor is properly grounded. Avoid using damaged or frayed electrical cords and ensure that the electrical connections are secure.

6. Lockout/Tagout Procedures:

  • Before performing any maintenance or repair tasks on the compressor, follow lockout/tagout procedures to isolate electrical power and prevent accidental startup. Lockout/tagout procedures help protect against unexpected energization of the compressor or its components.

7. Pressure Relief:

  • Before performing any maintenance tasks or opening the compressor, ensure that all pressure has been relieved from the system. Follow proper procedures for depressurizing the compressor and associated piping to avoid sudden releases of pressure.

8. Hot Surfaces:

  • Be cautious of hot surfaces, such as compressor casings, piping, or discharge components. Allow sufficient cooling time before touching or performing maintenance tasks on hot surfaces to avoid burns.

9. Maintenance and Inspection:

  • Adhere to the manufacturer’s recommended maintenance schedule and perform regular inspections of the compressor. Replace any worn or damaged components promptly to prevent potential hazards or malfunctions.

10. Emergency Procedures:

  • Be familiar with emergency procedures, including how to shut down the compressor in case of an emergency, how to respond to leaks or spills, and how to handle fire or electrical incidents. Have emergency contact information readily available.

11. Training and Qualified Personnel:

  • Ensure that operators and maintenance personnel are adequately trained in the safe operation and maintenance of screw compressors. Only allow qualified personnel to perform maintenance or repair tasks.

It is essential to consult the specific safety guidelines provided by the manufacturer of the screw compressor as they may include additional precautions or recommendations.

In summary, when operating screw compressors, it is important to familiarize yourself with the equipment, wear appropriate PPE, ensure proper ventilation, follow electrical safety measures, implement lockout/tagout procedures, be cautious of hot surfaces, perform regular maintenance and inspections, and be prepared with emergency procedures. By following these safety precautions, the risk of accidents or injuries can be minimized, ensuring a safe working environment when operating screw compressors.

air compressor

How Do Screw Compressors Contribute to Energy Savings?

Screw compressors offer several features and advantages that contribute to energy savings. Here’s a detailed explanation:

1. Efficient Compression Process:

Screw compressors are known for their efficiency in compressing air or gas. They use a unique rotary screw design, where two intermeshing screws rotate to compress the air. This design provides continuous and smooth compression, resulting in less energy loss compared to other compression technologies, such as reciprocating compressors. The efficient compression process of screw compressors helps reduce energy consumption.

2. Load and Unload Operation:

Screw compressors often incorporate load and unload operation, also known as capacity control. This feature allows the compressor to match its output to the actual demand for compressed air. During periods of lower demand, the compressor unloads by disengaging some of its capacity. This reduces power consumption since the compressor is not operating at full load continuously. By adjusting the compressor’s output to match the required air flow, load and unload operation helps save energy.

3. Variable Speed Drive (VSD) Technology:

Many screw compressors are equipped with Variable Speed Drive (VSD) technology. A VSD allows the compressor’s motor speed to be adjusted according to the demand for compressed air. By running the compressor at lower speeds during periods of lower demand, the energy consumption can be significantly reduced. The VSD technology enables precise control over the compressor’s output, resulting in energy savings and improved efficiency.

4. Air Leakage Reduction:

A common source of energy loss in compressed air systems is air leakage. Screw compressors are designed to minimize air leakage through improved sealing mechanisms and enhanced construction materials. By reducing air leakage, the compressor can operate more efficiently, as less energy is wasted in compressing air that escapes before reaching the intended point of use. Regular maintenance and monitoring practices help identify and address air leakage issues, further contributing to energy savings.

5. Integrated Energy Recovery:

In certain applications, screw compressors can be configured to recover and utilize the heat generated during the compression process. This recovered heat can be used for various purposes, such as space heating, preheating process air or water, or powering other thermal processes. By utilizing the recovered heat energy, screw compressors enhance overall energy efficiency and reduce the need for additional heating systems.

6. System Optimization and Controls:

Screw compressors often feature advanced control systems that optimize their operation for energy efficiency. These control systems monitor various parameters, such as system pressure, air demand, and temperature, and adjust the compressor’s operation accordingly. By continuously analyzing the system requirements and making intelligent adjustments, the control systems help minimize energy waste and maintain optimal performance.

7. Maintenance and Proper Operation:

Regular maintenance and proper operation of screw compressors are essential for maximizing energy savings. Routine maintenance activities, such as cleaning air filters, checking lubrication levels, and inspecting and repairing leaks, ensure the compressor operates at peak efficiency. Additionally, proper operation practices, such as avoiding excessive idling or overloading, contribute to energy savings and prolong the compressor’s lifespan.

In summary, screw compressors contribute to energy savings through their efficient compression process, load and unload operation, variable speed drive technology, air leakage reduction, integrated energy recovery, system optimization, and proper maintenance and operation. By utilizing these features and implementing energy-conscious practices, industries can significantly reduce energy consumption and lower operating costs in compressed air systems.

air compressor

What Are the Key Components of a Screw Compressor?

A screw compressor consists of several key components that work together to compress air or gas. Here’s a detailed explanation of these components:

1. Male and Female Rotors:

The male and female rotors are the primary components of a screw compressor. These helical rotors have specially designed profiles that interlock with each other. The male rotor typically has fewer lobes or threads compared to the female rotor. As the rotors rotate, the interlocking lobes create compression chambers that gradually reduce in volume, compressing the air or gas.

2. Compression Chamber:

The compression chamber is formed by the interlocking lobes of the rotors. It is the space where the air or gas is compressed as the rotors rotate. The volume of the compression chamber decreases as the lobes move towards the discharge end, resulting in the compression of the trapped air or gas.

3. Inlet and Outlet Ports:

The inlet port is the entry point through which the air or gas enters the screw compressor. It is typically located at the suction side of the compressor. The inlet port allows the air or gas to flow into the compression chamber during the suction process. The outlet port is the exit point through which the compressed air or gas is discharged from the compressor.

4. Drive System:

The drive system of a screw compressor consists of a motor and a drive mechanism. The motor provides the rotational power required to drive the rotors. Common types of drive mechanisms include direct drive, belt drive, and gear drive. The drive system ensures that the rotors rotate in opposite directions at the desired speed and synchronization.

5. Oil System (in oil-injected compressors):

In oil-injected screw compressors, an oil system is present to provide lubrication, cooling, and sealing between the rotors. The oil system typically includes an oil reservoir, an oil pump, oil filters, and oil coolers. The lubricating oil is injected into the compression chamber, where it forms a thin film on the rotors, reducing friction and minimizing wear.

6. Cooling System:

Screw compressors often incorporate a cooling system to maintain optimal operating temperatures. The cooling system may include air or water-cooled heat exchangers, which dissipate the heat generated during compression. Cooling ensures that the compressor operates within safe temperature limits, preventing overheating and prolonging the lifespan of the components.

7. Control System:

A control system is an essential component of a screw compressor, providing monitoring and regulation of various parameters. It may include sensors, controllers, and safety devices to measure and control variables such as pressure, temperature, and operating conditions. The control system ensures efficient and safe operation of the screw compressor.

8. Sound Attenuation and Vibration Isolation:

To reduce noise and vibration, screw compressors are often equipped with sound attenuation measures and vibration isolation systems. These components help in minimizing the noise and vibrations generated during operation, making the compressor suitable for noise-sensitive environments.

In summary, the key components of a screw compressor include the male and female rotors, compression chamber, inlet and outlet ports, drive system, oil system (in oil-injected compressors), cooling system, control system, and sound attenuation/vibration isolation components. These components work together to enable the efficient compression of air or gas in the screw compressor.

China best Lzn Series 15kw 22kw 16bar 20bar 230psi 290psi CHINAMFG Compression Screw Air Compressor Air Cooled Electirc Motor Powered Made for Cutting Application   with high qualityChina best Lzn Series 15kw 22kw 16bar 20bar 230psi 290psi CHINAMFG Compression Screw Air Compressor Air Cooled Electirc Motor Powered Made for Cutting Application   with high quality
editor by CX 2024-01-17

ml_INMalayalam